10 kV Variable Frequency Series Resonant Test System
AC withstand testing of 10 kV cables, switchgear and transformers, tuning to resonance anywhere from 30 to 300 Hz.
Test methods per IEC 60076
Test methods per IEC 62271-100
Test methods per IEEE 400.2 · IEC 60502
Test methods per IEC 60060-1 · IEC 60270
Test methods per IEC 60255 · IEC 61850
Test methods per IEC 61869
Test methods per IEEE 81
Test methods per IEC 60896
XB series resonant test system, 20–300 Hz, Q > 50, distortion < 1 %, units under 40 kg, for AC withstand tests on cables, transformers, GIS and generators.
Compare all 9 series resonant test systems and sizing guide →
The HUAC-XB series of variable frequency series resonant test systems performs AC withstand tests on power cables, transformers, GIS, switchgear and generators. Every unit weighs 40 kg or less, so the system is easy to carry and set up on site.
Three operating modes let the operator choose the fastest approach for the site: fully automatic, manual, or automatic tuning with manual voltage raising. During the automatic frequency sweep, the start frequency and the sweep direction can be set, and the LCD shows the sweep curve so it is clear when resonance has been found. The DSP platform allows functions to be added or upgraded to suit the user.
See all high voltage test equipment, or send us your requirements and we will recommend the right instrument.
| Output | |
|---|---|
| Waveform distortion | < 1.0 % |
| Frequency range | 20 – 300 Hz |
| Measurement accuracy | 1.5 % |
| Duty | |
| Continuous operation | 30 min at rated conditions; 60 min for 35 kV cable tests |
| Quality factor | |
| System | Q > 50 |
| Generators, full load | Q > 10 (depends on load) |
| Cables, full load | Q > 30 (depends on load) |
| Main transformers, full load | Q > 30 (depends on load) |
| GIS and switchgear, full load | Q > 50 (depends on load) |
| General | |
| Input supply | Single-phase 380 V |
| Max. unit weight | 40 kg |
| Interface language | English |
Specifications may change without notice. Contact us for the latest datasheet.
The datasheet and user manual for this instrument are sent on request, usually within one business day.
The XB series is configured to your test objects. Send us the capacitance or cable length, the test voltage and the test duration, and we will specify the reactors and power source.
30 minutes at rated conditions, and 60 minutes when testing 35 kV cables.
Flashover protection trips the output and the instrument records the flashover voltage for later analysis.
Have another question? Ask our application engineers.
Request a quote
Tell us the asset ratings and site conditions. A sales engineer will reply with a recommendation and quotation.
Related products
AC withstand testing of 10 kV cables, switchgear and transformers, tuning to resonance anywhere from 30 to 300 Hz.
Locate insulation defects in switchgear, cables and rotating machines before they fail.
Power frequency test transformer with control console, rated output 0–430 kV, for AC withstand tests; DC output with an external rectifier stack.
Request a quote
A sales engineer replies within one business day.Or emailsales@huactester.com.