Circuit Breaker Analyzer with 9-Inch Touch Screen and Bluetooth
Circuit breaker analyzer for timing, bounce, travel, speed and coil current, with built-in 6–270 V supply, 9-inch touch screen, printer and Bluetooth.
Test methods per IEC 60076
Test methods per IEC 62271-100
Test methods per IEEE 400.2 · IEC 60502
Test methods per IEC 60060-1 · IEC 60270
Test methods per IEC 60255 · IEC 61850
Test methods per IEC 61869
Test methods per IEEE 81
Test methods per IEC 60896
Circuit breaker timing, reclosing, bounce, speed, travel and coil current tester for 12 breaks, with built-in DC 0–300 V / 20 A operating supply.
The HUAC-GKC-6 tests the dynamic characteristics of high-voltage circuit breakers. It measures the opening and closing times of 12 breaks, synchronism within and between phases, the full reclosing sequence, contact bounce, speed, travel and coil current.
A built-in, digitally adjustable DC 0–300 V / 20 A operating supply performs low-voltage operation tests automatically and measures the actual operating voltage of the breaker.
Choose the HUAC-GKC-6 for routine timing, reclosing, bounce, travel and coil current tests on breakers with up to 12 breaks. Its operating supply starts from 0 V (DC 0–300 V, 20 A), which suits low-voltage operation tests.
Consider the HUAC-GK if you need PC software for formal reports, or the HUAC-GKC-HA for a touch screen and more communication interfaces.
See all circuit breaker test equipment, or send us your switchgear data and we will recommend the right instrument.
| Time | |
|---|---|
| Range | 20,000.0 ms |
| Resolution | 0.01 ms |
| Error (200 ms range) | 0.01 ms ±2 digits |
| Error (2000 ms range) | 0.1 ms ±2 digits |
| Error (20,000 ms range) | 1 ms ±2 digits |
| Speed | |
| Range / resolution | 20.00 m/s / 0.01 m/s |
| Error | ±0.1 m/s ±1 digit (0 – 2 m/s); ±0.2 m/s ±1 digit (> 2 m/s) |
| Coil | |
| Current | 10.00 A range, 0.01 A resolution |
| DC output | |
| Operating supply | DC 0 – 300 V digitally adjustable, 20 A momentary, 1 V resolution |
| Safety | |
| Insulation resistance | > 2 MΩ |
| Dielectric strength | 1.5 kV, 1 min to chassis |
| General | |
| Interface language | English |
Specifications may change without notice. Contact us for the latest datasheet.
The datasheet and user manual for this instrument are sent on request, usually within one business day.
For close-open, open-close and open-close-open sequences it records the first opening time, the closing times and the dead time between operations.
Yes. The built-in DC 0–300 V supply performs them automatically and measures the actual operating voltage.
12.
Have another question? Ask our application engineers.
Request a quote
Tell us the asset ratings and site conditions. A sales engineer will reply with a recommendation and quotation.
Related products
Circuit breaker analyzer for timing, bounce, travel, speed and coil current, with built-in 6–270 V supply, 9-inch touch screen, printer and Bluetooth.
12-channel circuit breaker analyzer with mobile app control over Bluetooth, 7-inch sunlight-readable screen, built-in 20–270 V supply and printer.
12-channel circuit breaker timing and travel tester with dry contact outputs, built-in DC 20–270 V supply, linear and rotary sensors, -20 to +50 °C.
Request a quote
A sales engineer replies within one business day.Or emailsales@huactester.com.