Three-Phase Transformer Turns Ratio Tester (TTR), Battery Powered
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.
Test methods per IEC 60076
Test methods per IEC 62271-100
Test methods per IEEE 400.2 · IEC 60502
Test methods per IEC 60060-1 · IEC 60270
Test methods per IEC 60255 · IEC 61850
Test methods per IEC 61869
Test methods per IEEE 81
Test methods per IEC 60896
Single- and three-phase transformer turns ratio tester with vector group, blind test and built-in thermal printer. Ratio 0.9 to 5000, 4 kg, 220 V AC.
Turns ratio testing is required on new, repaired and in-service transformers to check the windings and tap changer for shorted turns, wrong connections and other defects. The HUAC-BBZ-1000 measures the turns ratio of single-phase and three-phase transformers in one operation.
A 32-bit ARM processor controls the whole measurement. The tester has strong immunity to interference, prints the results on its built-in thermal printer and suits transformers from small distribution units to large power transformers.
Choose the HUAC-BBZ-1000 if you need a printed record on site, test Z-connected (zigzag) transformers, or test single-phase and three-phase units where AC 220 V is always available.
Consider the HUAC-2071 or HUAC-BB if you need battery operation, ratios above 5000, more than 50 stored results or USB export of reports in Word format.
See the full range of transformer test equipment, or send us your transformer data and we will recommend the right instrument.
| Measurement | |
|---|---|
| Ratio range | 0.9 – 5000 |
| Accuracy (0.9 – 2000) | ±(0.2 % + 3 digits) |
| Accuracy (2000 – 5000) | ±(0.5 % + 3 digits) |
| Test voltage | 220 V AC |
| Data | |
| Memory | 50 results |
| Printer | Built-in thermal printer |
| General | |
| Power supply | 220 V AC ±10 %, 50 Hz ±1 Hz |
| Dimensions | 345 × 245 × 225 mm |
| Weight | 4 kg |
| Operating temperature | -10 – 40 °C |
| Relative humidity | < 80 %, non-condensing |
| Interface language | English |
Specifications may change without notice. Contact us for the latest datasheet.
The datasheet and user manual for this instrument are sent on request, usually within one business day.
It confirms that the windings and tap changer are correct and finds shorted turns, wrong connections and tap changer defects before the transformer is put into service.
About 10 seconds per phase.
Yes. The built-in thermal printer prints each result immediately.
Have another question? Ask our application engineers.
Request a quote
Tell us the asset ratings and site conditions. A sales engineer will reply with a recommendation and quotation.
Related products
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.
Fully automatic three-phase turns ratio tester with colour screen and blind test: ratio, vector group and polarity, ratio up to 10,000, battery or AC powered.
40 A transformer winding resistance tester, 0.1 mΩ to 25 kΩ, ±0.2 %, with 7-inch touch screen, printer and automatic resistance-stability check.
Request a quote
A sales engineer replies within one business day.Or emailsales@huactester.com.