Three-Phase Transformer Turns Ratio Tester (TTR), Battery Powered
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.
Test methods per IEC 60076
Test methods per IEC 62271-100
Test methods per IEEE 400.2 · IEC 60502
Test methods per IEC 60060-1 · IEC 60270
Test methods per IEC 60255 · IEC 61850
Test methods per IEC 61869
Test methods per IEEE 81
Test methods per IEC 60896
Fully automatic three-phase turns ratio tester with colour screen and blind test: ratio, vector group and polarity, ratio up to 10,000, battery or AC powered.
The HUAC-BB fully automatic turns ratio tester replaces the slow, manual ratio bridge. It measures ratio, vector group and polarity on all three phases in one sequence, in about 10 seconds, and shows the results on a large colour screen.
It tests distribution transformers, power transformers up to 1000 kV, single-phase transformers, CTs, PTs and Z-connected transformers. The blind-test function finds the ratio and vector group when the winding connections are unknown. The instrument runs from its internal battery or from an AC charger.
Choose the HUAC-BB if you want a large colour screen with menu-driven operation. It has the same ratio range (0.9 to 10,000), 197 tap positions and battery operation as the HUAC-2071.
Consider the HUAC-2071 if size and weight matter most (3.5 kg against 3.8 kg, in a smaller case), or the HUAC-BBZ-1000 if you need a built-in printer or test Z-connected transformers.
See the full range of transformer test equipment, or send us your transformer data and we will recommend the right instrument.
| Measurement | |
|---|---|
| Ratio range | 0.9 – 10,000 |
| Accuracy (ratio ≤ 500) | ±(0.2 % of reading + 2 digits) |
| Accuracy (ratio > 500) | ±(0.5 % of reading + 2 digits) |
| Resolution | 0.0001 (ratio 0.9 – 9.9999) |
| Power | |
| Supply | Built-in battery or external charger |
| Charger input | 100 – 240 V AC, 50 / 60 Hz |
| Charging time | Approx. 5 h |
| General | |
| Dimensions | 380 × 310 × 150 mm |
| Weight | 3.8 kg |
| Operating temperature | -10 – 50 °C |
| Relative humidity | < 90 %, non-condensing |
| Interface language | English |
Specifications may change without notice. Contact us for the latest datasheet.
The datasheet and user manual for this instrument are sent on request, usually within one business day.
A ratio bridge is balanced by hand, one phase at a time, and the result has to be calculated. This tester measures all three phases automatically and displays ratio, error, vector group and polarity directly.
Yes, as well as single-phase and Z-connected transformers.
Up to 500 results are stored in the instrument and can be copied to a USB flash drive as Word files for editing and printing.
Have another question? Ask our application engineers.
Request a quote
Tell us the asset ratings and site conditions. A sales engineer will reply with a recommendation and quotation.
Related products
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.
Single- and three-phase transformer turns ratio tester with vector group, blind test and built-in thermal printer. Ratio 0.9 to 5000, 4 kg, 220 V AC.
40 A transformer winding resistance tester, 0.1 mΩ to 25 kΩ, ±0.2 %, with 7-inch touch screen, printer and automatic resistance-stability check.
Request a quote
A sales engineer replies within one business day.Or emailsales@huactester.com.