Three-Phase Transformer Turns Ratio Tester (TTR), Battery Powered
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.
Test methods per IEC 60076
Test methods per IEC 62271-100
Test methods per IEEE 400.2 · IEC 60502
Test methods per IEC 60060-1 · IEC 60270
Test methods per IEC 60255 · IEC 61850
Test methods per IEC 61869
Test methods per IEEE 81
Test methods per IEC 60896
Combined winding deformation tester using frequency response analysis and low-voltage short-circuit impedance for medium and large power transformers.
The HUAC-RZ-II combines two methods for diagnosing transformer windings: frequency response analysis (FRA) and the low-voltage short-circuit impedance method. Using both gives a fuller picture of the winding condition of medium and large power transformers.
Once the input and output signals are connected, a measurement runs with a single button. The software calculates the relevant parameters, diagnoses the degree of winding deformation and gives a reference conclusion. The instrument travels in a shock-proof, moisture-resistant case.
See the full range of transformer test equipment, or send us your transformer data and we will recommend the right instrument.
| FRA | |
|---|---|
| Sweep range | 1 kHz – 2000 kHz, linear or logarithmic |
| Signal source | Sine wave, max. ±10 V, 50 Ω output |
| Response input | Max. ±25 V, 1 MΩ, auto range |
| Resolution / sampling | 16-bit, 20 MS/s per channel |
| Static error | < 0.2 % |
| Frequency accuracy | ≤ 0.01 % |
| Impedance | |
| Voltage | 15 – 500 V, ±1 % |
| Current | 0.25 – 50 A, ±1 % |
| Impedance | 0 – 100 %, ±1 % |
| Active power | ±0.2 % (0.1 < cos φ ≤ 1); ±0.5 % (0.02 < cos φ ≤ 0.1) |
| Frequency | 45 – 65 Hz, ±0.05 % |
| General | |
| Interface language | English |
Specifications may change without notice. Contact us for the latest datasheet.
The datasheet and user manual for this instrument are sent on request, usually within one business day.
FRA is sensitive to local changes in the winding, while short-circuit impedance reflects the overall leakage reactance. Together they give a more reliable diagnosis.
Medium and large power transformers.
Yes, the analysis software runs on a Windows computer.
Have another question? Ask our application engineers.
Request a quote
Tell us the asset ratings and site conditions. A sales engineer will reply with a recommendation and quotation.
Related products
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.
Fully automatic three-phase turns ratio tester with colour screen and blind test: ratio, vector group and polarity, ratio up to 10,000, battery or AC powered.
Single- and three-phase transformer turns ratio tester with vector group, blind test and built-in thermal printer. Ratio 0.9 to 5000, 4 kg, 220 V AC.
Request a quote
A sales engineer replies within one business day.Or emailsales@huactester.com.