10 kV Variable Frequency Series Resonant Test System
AC withstand testing of 10 kV cables, switchgear and transformers, tuning to resonance anywhere from 30 to 300 Hz.
Test methods per IEC 60076
Test methods per IEC 62271-100
Test methods per IEEE 400.2 · IEC 60502
Test methods per IEC 60060-1 · IEC 60270
Test methods per IEC 60255 · IEC 61850
Test methods per IEC 61869
Test methods per IEEE 81
Test methods per IEC 60896
Power frequency test transformer with control console, rated output 0–430 kV, for AC withstand tests; DC output with an external rectifier stack.
The HUAC YDQ / YDJ power frequency withstand test sets combine a test transformer with a matching control console for AC withstand tests on electrical equipment, with a rated output voltage of 0 to 430 kV. New design, materials and manufacturing make the test transformers small, light and well finished, and they meet the requirements of JB 3570.
The core is stacked from high-grade cold-rolled grain-oriented silicon steel into a multi-step cylindrical frame, and the high-voltage tower winding is wound continuously on a high-strength insulating cylinder. The standard output is AC; for DC tests, an external high-voltage rectifier stack is fitted at the high-voltage terminal.
See all high voltage test equipment, or send us your requirements and we will recommend the right instrument.
| Test transformer | |
|---|---|
| Rated output voltage | 0 – 430 kV |
| Control console | |
| CX-3 | 3 kVA; supply 1-phase 220 V 50 Hz; output 250 V, 12 A |
| CX-5 | 5 kVA; supply 1-phase 220 V 50 Hz; output 250 V, 20 A |
| CX-10 | 10 kVA; supply 1-phase 220 V 50 Hz; output 250 V, 40 A |
| CX-15 | 15 kVA; supply 220 / 380 V 50 Hz; output 250 / 450 V, 60 / 33.3 A |
| CX-20 | 20 kVA; supply 380 V 50 Hz; output 450 V, 44.4 A |
| CX-30 | 30 kVA; supply 380 V 50 Hz; output 450 V, 66.6 A |
| CX-50 | 50 kVA; supply 380 V 50 Hz; output 400 V, 125 A |
| General | |
| Output | AC; DC with external HV rectifier stack |
| Interface language | English |
Specifications may change without notice. Contact us for the latest datasheet.
The datasheet and user manual for this instrument are sent on request, usually within one business day.
Fit the external high-voltage rectifier stack at the high-voltage output of the test transformer.
The rated output voltage is 0 to 430 kV. Tell us the equipment you test and the required test voltage and current, and we will match the test transformer and control console.
Single-phase 220 V for consoles up to 10 kVA; 380 V for 20 kVA and above. The 15 kVA console is available for either.
Have another question? Ask our application engineers.
Request a quote
Tell us the asset ratings and site conditions. A sales engineer will reply with a recommendation and quotation.
Related products
AC withstand testing of 10 kV cables, switchgear and transformers, tuning to resonance anywhere from 30 to 300 Hz.
Locate insulation defects in switchgear, cables and rotating machines before they fail.
XB series resonant test system, 20–300 Hz, Q > 50, distortion < 1 %, units under 40 kg, for AC withstand tests on cables, transformers, GIS and generators.
Request a quote
A sales engineer replies within one business day.Or emailsales@huactester.com.