Three-Phase Transformer Turns Ratio Tester (TTR), Battery Powered
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.
Test methods per IEC 60076
Test methods per IEC 62271-100
Test methods per IEEE 400.2 · IEC 60502
Test methods per IEC 60060-1 · IEC 60270
Test methods per IEC 60255 · IEC 61850
Test methods per IEC 61869
Test methods per IEEE 81
Test methods per IEC 60896
Automatic tan delta and capacitance tester with built-in 10 kV source and 45/55 Hz anti-interference, for transformers, CVTs and other HV equipment.
The HUAC-JS-1000 measures the dissipation factor (tan δ) and capacitance of high-voltage power equipment such as transformers and capacitive voltage transformers (CVTs), on site in power plants and substations or in the laboratory.
It uses variable-frequency measurement at 45 / 55 Hz to stay accurate under strong electric-field interference. A built-in step-up transformer provides 0.5 to 10 kV in 500 V steps, so no external high-voltage source is needed. Normal and reverse connection cover both ungrounded and grounded test objects, and the C1 and C2 of CVTs can be measured.
See the full range of transformer test equipment, or send us your transformer data and we will recommend the right instrument.
| Output | |
|---|---|
| High voltage | 0.5 – 10 kV, 500 V steps (20 steps) |
| Capacity | 1500 VA |
| Accuracy | |
| tan δ | ±(1.5 % of reading + 0.04 %) |
| Cx | ±(1.5 % of reading + 5 pF) |
| Resolution | |
| tan δ / Cx | 0.01 % / 1 pF |
| Range | |
| tan δ | 0.1 % – 100 % |
| Cx | 3 pF – 60,000 pF (≤ 30,000 pF at 10 kV) |
| Measurement | |
| Frequency | 50 Hz, or 45 / 55 Hz automatic variable frequency |
| Harmonic tolerance | ≤ 3 % |
| General | |
| Power supply | 220 V AC ±10 %, 50 Hz ±1 Hz |
| Dimensions | 460 × 345 × 350 mm |
| Weight | 35 kg |
| Operating conditions | -15 – 50 °C, RH < 80 % |
| Interface language | English |
Specifications may change without notice. Contact us for the latest datasheet.
The datasheet and user manual for this instrument are sent on request, usually within one business day.
The dissipation factor shows the dielectric losses in insulation. An increase compared with earlier measurements indicates moisture, contamination or ageing of the insulation.
In substations, 50 Hz interference from live equipment disturbs measurements. Measuring at 45 and 55 Hz and combining the results removes the interference.
Yes. It measures the tan δ and capacitance of the main capacitors C1 and C2 of capacitive voltage transformers.
Have another question? Ask our application engineers.
Request a quote
Tell us the asset ratings and site conditions. A sales engineer will reply with a recommendation and quotation.
Related products
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.
Fully automatic three-phase turns ratio tester with colour screen and blind test: ratio, vector group and polarity, ratio up to 10,000, battery or AC powered.
Single- and three-phase transformer turns ratio tester with vector group, blind test and built-in thermal printer. Ratio 0.9 to 5000, 4 kg, 220 V AC.
Request a quote
A sales engineer replies within one business day.Or emailsales@huactester.com.