Three-Phase Transformer Turns Ratio Tester (TTR), Battery Powered
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.
Test methods per IEC 60076
Test methods per IEC 62271-100
Test methods per IEEE 400.2 · IEC 60502
Test methods per IEC 60060-1 · IEC 60270
Test methods per IEC 60255 · IEC 61850
Test methods per IEC 61869
Test methods per IEEE 81
Test methods per IEC 60896
Identifies copper or aluminium windings and measures capacity, losses and DC resistance of transformers. Battery powered, 7-inch touch screen.
Some transformers are sold as copper-wound when their windings are actually aluminium, and some users under-declare transformer capacity. This analyzer is designed for these problems: it identifies the winding material of a transformer from the different electrical characteristics of copper and aluminium, and measures its real capacity.
It combines three instruments in one: a transformer capacity tester, a transformer characteristic (loss) tester and a winding material analyzer. A built-in battery and three-phase 50 Hz source mean capacity and load loss can be measured with no external supply; one charge covers more than 100 transformers. A DC resistance function with six current levels up to 10 A is included.
See the full range of transformer test equipment, or send us your transformer data and we will recommend the right instrument.
| Built-in source | |
|---|---|
| Voltage / current | 0 – 10 V / 0 – 10 A |
| Characteristic test | |
| Voltage | AC 750 V, ±0.2 % FS ±1 digit |
| Current | AC 100 A, ±0.2 % FS ±1 digit |
| Accuracy | |
| Power | ±0.5 % FS (cos φ > 0.1); ±1.0 % FS (0.02 < cos φ < 0.1) |
| No-load / load loss | ±2 % (0.1 ≤ cos φ ≤ 1) |
| DC resistance | |
| Ranges | 0.001 – 0.1 Ω (10 A) … 100 Ω – 100 kΩ (< 5 mA) |
| Accuracy | 0.2 % ±2 µΩ |
| Resolution | 0.1 µΩ |
| Capacity test | |
| Range | 6.3 – 125,000 kVA |
| General | |
| Charger input | 160 – 265 V AC |
| Operating temperature | -20 – 60 °C |
| Interface language | English |
Specifications may change without notice. Contact us for the latest datasheet.
The datasheet and user manual for this instrument are sent on request, usually within one business day.
Copper and aluminium windings have different electrical characteristics. The analyzer measures these and identifies the winding material without opening the transformer.
Not for capacity and material tests: the built-in battery and three-phase source supply the test signal. For no-load and load loss tests, an external supply and regulator are used.
Utilities checking customer transformers, and buyers who want to verify transformers on delivery.
Have another question? Ask our application engineers.
Request a quote
Tell us the asset ratings and site conditions. A sales engineer will reply with a recommendation and quotation.
Related products
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.
Fully automatic three-phase turns ratio tester with colour screen and blind test: ratio, vector group and polarity, ratio up to 10,000, battery or AC powered.
Single- and three-phase transformer turns ratio tester with vector group, blind test and built-in thermal printer. Ratio 0.9 to 5000, 4 kg, 220 V AC.
Request a quote
A sales engineer replies within one business day.Or emailsales@huactester.com.