Three-Phase Transformer Turns Ratio Tester (TTR), Battery Powered
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.
Test methods per IEC 60076
Test methods per IEC 62271-100
Test methods per IEEE 400.2 · IEC 60502
Test methods per IEC 60060-1 · IEC 60270
Test methods per IEC 60255 · IEC 61850
Test methods per IEC 61869
Test methods per IEEE 81
Test methods per IEC 60896
Transformer capacity, no-load and load-loss tester with 7-inch touch screen: checks distribution transformer capacity and energy efficiency class on site.
The HUAC-506D measures the capacity, no-load loss and load loss of distribution transformers and judges their energy efficiency class on site. It switches ranges internally, so voltage and current are measured over a wide range with simple wiring.
One unit carries out load tests at full rated current on distribution transformers up to 1000 kVA, and at one-third of rated current on transformers up to 3150 kVA, converting the result to rated-current load loss automatically. All results are corrected automatically. External voltage and current transformers extend the range further.
See the full range of transformer test equipment, or send us your transformer data and we will recommend the right instrument.
| Capacity test | |
|---|---|
| Output current | 0 – 10 A |
| Voltage measurement | 0 – 10 V |
| Capacity range | 30 – 65,000 kVA |
| Characteristic test | |
| Voltage | 20 – 650 V |
| Current | 0.5 – 100 A |
| Frequency | 45 – 65 Hz |
| Accuracy | |
| Voltage, current | ±(0.2 % of reading + 2 digits) |
| Power (0.2 ≤ cos φ ≤ 1) | ±(1.0 % of reading + 2 digits) |
| Capacity | ±(10 % of reading + 2 digits) |
| General | |
| Insulation | ≥ 100 MΩ to case; 2 kV for 1 min at power input |
| Dimensions | 380 × 310 × 155 mm |
| Weight | 4.5 kg (without leads) |
| Interface language | English |
| Environment | |
| Temperature | -20 – 50 °C |
| Humidity | 10 – 85 % |
| Altitude | < 2500 m |
Specifications may change without notice. Contact us for the latest datasheet.
The datasheet and user manual for this instrument are sent on request, usually within one business day.
To check that a distribution transformer really has the capacity on its nameplate, for example when receiving new units or auditing installed transformers.
Yes. Up to 3150 kVA it tests at one-third of rated current and converts the result. With external VTs and CTs the range can be extended further.
It measures losses low enough to judge oil-immersed transformers down to class S22 (electrical steel) and SH25 (amorphous alloy), and dry-type transformers down to SCB18 and SCBH19, under the Chinese energy efficiency classification.
Have another question? Ask our application engineers.
Request a quote
Tell us the asset ratings and site conditions. A sales engineer will reply with a recommendation and quotation.
Related products
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.
Fully automatic three-phase turns ratio tester with colour screen and blind test: ratio, vector group and polarity, ratio up to 10,000, battery or AC powered.
Single- and three-phase transformer turns ratio tester with vector group, blind test and built-in thermal printer. Ratio 0.9 to 5000, 4 kg, 220 V AC.
Request a quote
A sales engineer replies within one business day.Or emailsales@huactester.com.