Three-Phase Transformer Turns Ratio Tester (TTR), Battery Powered
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.
Test methods per IEC 60076
Test methods per IEC 62271-100
Test methods per IEEE 400.2 · IEC 60502
Test methods per IEC 60060-1 · IEC 60270
Test methods per IEC 60255 · IEC 61850
Test methods per IEC 61869
Test methods per IEEE 81
Test methods per IEC 60896
Three-channel OLTC analyzer recording A, B and C phases at once: transition waveform, time, resistance and synchronism, with printer and 128 waveform memory.
The HUAC-KC-2002 measures and analyses the electrical performance of on-load tap changers in power transformers and special transformers. Three independent channels record phases A, B and C at the same time and capture the transition resistance and timing during each tap change.
Measurements can be made through the tap changer leads or directly on the transformer’s three-phase bushings and neutral. Dedicated function keys analyse each segment of the waveform for time and resistance. An aluminium-alloy case with power filters and anti-interference circuits keeps readings reliable in substations.
See the full range of transformer test equipment, or send us your transformer data and we will recommend the right instrument.
| Output | |
|---|---|
| Test sources | 3 independent, max. 0.5 A |
| Measurement | |
| Sampling rate | 10 – 20 kHz configurable |
| Max. record length | 6.4 s |
| Transition resistance | 1 – 40 Ω (Y0); 1 – 20 Ω (Y) |
| Accuracy | |
| Resistance | ≤ ±10 % (1 – 5 Ω); ≤ ±5 % (5 – 40 Ω) |
| Time | ≤ ±1 % |
| Data | |
| Memory | 128 waveforms; serial transfer to PC |
| General | |
| Power supply | 220 V ±10 %, ≤ 200 W |
| Dimensions | 410 × 320 × 200 mm |
| Weight | ≤ 20 kg |
| Interface language | English |
Specifications may change without notice. Contact us for the latest datasheet.
The datasheet and user manual for this instrument are sent on request, usually within one business day.
Recording all three phases at once shows the switching sequence and synchronism of the tap changer in one operation.
Either to the tap changer leads or directly to the transformer’s three-phase bushings and neutral point.
Up to 128 waveforms are stored and kept after power loss, and can be transferred to a PC.
Have another question? Ask our application engineers.
Request a quote
Tell us the asset ratings and site conditions. A sales engineer will reply with a recommendation and quotation.
Related products
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.
Fully automatic three-phase turns ratio tester with colour screen and blind test: ratio, vector group and polarity, ratio up to 10,000, battery or AC powered.
Single- and three-phase transformer turns ratio tester with vector group, blind test and built-in thermal printer. Ratio 0.9 to 5000, 4 kg, 220 V AC.
Request a quote
A sales engineer replies within one business day.Or emailsales@huactester.com.