Three-Phase Transformer Turns Ratio Tester (TTR), Battery Powered
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.
Test methods per IEC 60076
Test methods per IEC 62271-100
Test methods per IEEE 400.2 · IEC 60502
Test methods per IEC 60060-1 · IEC 60270
Test methods per IEC 60255 · IEC 61850
Test methods per IEC 61869
Test methods per IEEE 81
Test methods per IEC 60896
Lightweight 5 kg OLTC tester for transition waveform, time, resistance and three-phase synchronism, with 5.7-inch screen and USB storage.
The HUAC-KC-2008 measures the key parameters of transformer on-load tap changers: transition waveform, transition time, transition resistance and three-phase synchronism. It calculates transition resistance and time automatically.
Two current ranges give a wider measuring range with stable readings, and at 5 kg the instrument is easy to take up to the transformer.
See the full range of transformer test equipment, or send us your transformer data and we will recommend the right instrument.
| Output | |
|---|---|
| Test current | 1.0 A, 0.5 A |
| Measurement | |
| Transition resistance | 0.5 – 20 Ω (1.0 A); 0.5 – 40 Ω (0.5 A) |
| Transition time | 2 – 250 ms |
| Accuracy | |
| Transition resistance | ±(5 % of reading + 3 digits) |
| Transition time | ±(0.1 % of reading + 3 digits) |
| Data | |
| Storage | Internal memory and USB flash drive |
| General | |
| Dimensions | 345 × 295 × 175 mm |
| Weight | 5 kg |
| Interface language | English |
Specifications may change without notice. Contact us for the latest datasheet.
The datasheet and user manual for this instrument are sent on request, usually within one business day.
Transition waveform, transition time, transition resistance and three-phase synchronism of on-load tap changers.
The KC-2008 is lighter and simpler for routine field tests. The BYKC-III adds a touch screen, automatic fault marking and Word reports.
In internal memory and on a USB flash drive, including the waveforms.
Have another question? Ask our application engineers.
Request a quote
Tell us the asset ratings and site conditions. A sales engineer will reply with a recommendation and quotation.
Related products
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.
Fully automatic three-phase turns ratio tester with colour screen and blind test: ratio, vector group and polarity, ratio up to 10,000, battery or AC powered.
Single- and three-phase transformer turns ratio tester with vector group, blind test and built-in thermal printer. Ratio 0.9 to 5000, 4 kg, 220 V AC.