Three-Phase Transformer Turns Ratio Tester (TTR), Battery Powered
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.
Test methods per IEC 60076
Test methods per IEC 62271-100
Test methods per IEEE 400.2 · IEC 60502
Test methods per IEC 60060-1 · IEC 60270
Test methods per IEC 60255 · IEC 61850
Test methods per IEC 61869
Test methods per IEEE 81
Test methods per IEC 60896
Automatic transformer oil BDV tester, 0–80 kV: raises, holds, stirs, stands, calculates and prints the breakdown voltage and average automatically.
The HUAC-8000 measures the dielectric strength (breakdown voltage, BDV) of transformer and other insulating oils. A microcontroller runs the whole test automatically: raising the voltage, holding, stirring, standing, calculating and printing, with repeated breakdown tests up to 80 kV.
The operator only sets the test parameters; the instrument then tests one cup of oil to the set sequence, stores each breakdown voltage and prints every value and the average on its thermal printer. The voltage is raised at a constant, controlled rate at an accurate 50 Hz, and the compact instrument is easy to carry.
See all transformer test equipment, or send us your requirements and we will recommend the right instrument.
| Output | |
|---|---|
| Test voltage | 0 – 80 kV |
| Voltage distortion | < 3 % |
| Transformer capacity | 1.5 kVA |
| Sequence | |
| Rise rate | 0.5 – 5 kV/s, adjustable |
| Standing time | 15 min, adjustable |
| Interval between breakdowns | 5 min, adjustable |
| Number of breakdowns | 1 – 9, selectable |
| Measurement | |
| Accuracy | ±3 % |
| Data | |
| Memory | 100 results |
| General | |
| Power supply | 220 V AC ±10 %, 50 Hz ±1 Hz |
| Power consumption | 200 W |
| Interface language | English |
| Environment | |
| Conditions | 0 – 45 °C, RH < 75 % |
Specifications may change without notice. Contact us for the latest datasheet.
The datasheet and user manual for this instrument are sent on request, usually within one business day.
The breakdown voltage of insulating oil drops when the oil contains water, particles or other contamination, so it is a quick check of oil condition.
Yes. Rise rate, standing time, interval between breakdowns and the number of breakdowns are all adjustable.
Each breakdown value and the average are printed on the built-in thermal printer and stored in memory; an RS232 link to a PC is optional.
Have another question? Ask our application engineers.
Request a quote
Tell us the asset ratings and site conditions. A sales engineer will reply with a recommendation and quotation.
Related products
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.
Fully automatic three-phase turns ratio tester with colour screen and blind test: ratio, vector group and polarity, ratio up to 10,000, battery or AC powered.
Single- and three-phase transformer turns ratio tester with vector group, blind test and built-in thermal printer. Ratio 0.9 to 5000, 4 kg, 220 V AC.
Request a quote
A sales engineer replies within one business day.Or emailsales@huactester.com.