Three-Phase Transformer Turns Ratio Tester (TTR), Battery Powered
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.
Test methods per IEC 60076
Test methods per IEC 62271-100
Test methods per IEEE 400.2 · IEC 60502
Test methods per IEC 60060-1 · IEC 60270
Test methods per IEC 60255 · IEC 61850
Test methods per IEC 61869
Test methods per IEEE 81
Test methods per IEC 60896
Fully automatic insulating oil acid value tester using the extraction method: 1–6 samples per run, 0.002–1 mg KOH/g, automatic cleaning and printing.
The HUAC-3136 determines the acid value of insulating oil by the extraction method, fully automatically, with a colour screen. It improves efficiency and accuracy while reducing the operator’s contact with samples and reagents.
Put the samples in the sample cups and place them in the instrument: it finds the samples, adds the extraction liquid, titrates the blank, measures, cleans itself, displays and prints the results. One start measures 1 to 6 samples. A standard acid and calibration program let the user calibrate the instrument and the neutralising solution at any time, and the instrument subtracts the background value of the extraction liquid automatically, for more reliable results.
See all transformer test equipment, or send us your requirements and we will recommend the right instrument.
| Measurement | |
|---|---|
| Range | 0.002 – 1 mg KOH/g |
| Error | ≤ ±0.005 mg KOH/g |
| Repeatability | ≤ 0.005 mg KOH/g |
| Samples per run | 1 – 6 |
| General | |
| Power supply | 220 V AC, 50 Hz |
| Power consumption | 50 W |
| Interface language | English |
| Environment | |
| Conditions | 10 – 45 °C, RH ≤ 85 % |
Specifications may change without notice. Contact us for the latest datasheet.
The datasheet and user manual for this instrument are sent on request, usually within one business day.
Acids form as the oil oxidises and ages. A rising acid value is an early sign of oil degradation that attacks the paper insulation.
1 to 6 samples per run.
No. The instrument titrates a blank and subtracts the background value of the extraction liquid automatically.
Have another question? Ask our application engineers.
Request a quote
Tell us the asset ratings and site conditions. A sales engineer will reply with a recommendation and quotation.
Related products
Battery-powered three-phase TTR tester: ratio, vector group and polarity in about 10 seconds with one connection, ratio 0.9 to 10,000, 3.5 kg.